IRTP-240
Metal-ceramic X-ray tubes IRTP-240 are to be used in X-ray equipment Arina-7 and Arina-9. It has higher power and longer operation time.
Characteristic, unit measure |
IRTP - 240 |
|||
rate |
test data |
|||
min |
nominal |
max |
||
Pulse voltage amplitude, kv |
180 |
210 |
240 |
|
Focus spot diameter, mm |
- |
3 ± 0.5 |
- |
3 ± 0.5 |
X-ray radiation exposure doze behind the steel barrier of 40 mm |
30 И 10-3 |
- |
- |
(50-60) И 10-3 |
Warranty operation time, pulses |
|
106 |
|
106 |
Size, d x l, mm |
|
62 И 100 |
|
|
Mass, kg, max |
|
0.3 |
|
|
Characteristic of measurement mode |
||||
Capacity discharge on the tube, pf |
- |
50 |
- |
|
X-ray flares' repetition rate, Hz |
- |
10 |
- |
|
Exposure time, sec |
- |
60 ± 1 |
|
|
After-Sales


The goods are custom-made.
Please, call us and agree on the delivery time with our manager.
+7 4912 24-90-92